Monitoring the Value of a Parameter
Follow this procedure when you want to see or change a parameter value of an Add-On Instruction.
1. Open the Properties of the instruction based on what language you are using.
a. For either a Function Block or Ladder Diagram, click Properties for the instruction.
b. For Structured Text, right-click the instruction name and choose Properties.
Motor_Starter(Motor_Starter_ST,
Stop_PB,Start_PB,Motor_Out_ST);
2. Monitor the value of the parameters and change any if needed.
3. Type a new value for each parameter as needed.
4. Click Apply and when finished, OK.
1. Open the Properties of the instruction based on what language you are using.
a. For either a Function Block or Ladder Diagram, click Properties for the instruction.
b. For Structured Text, right-click the instruction name and choose Properties.
Motor_Starter(Motor_Starter_ST,
Stop_PB,Start_PB,Motor_Out_ST);
2. Monitor the value of the parameters and change any if needed.
3. Type a new value for each parameter as needed.
4. Click Apply and when finished, OK.