Using GSV and SSV Instructions

When using GSV and SSV instructions inside an Add-On Instruction, the following classes are supported:

· AddOnInstructionDefinition(1)(2)
· MotionGroup
· Axis
· Program(2)
· Controller
· Routine(2)
· Controller Device
· Redundancy
· CoordinateSystem
· Safety
· CST
· Serial Port
· DF1
· Task(2)
· Fault Log
· Wall Clock Time
· Message

(1) GSV-only. SSV instructions will not verify.
(2) The classes that represent programming components - Task, Program, Routine, AddOnInstructionDefinition - support only this as the Instance Name.

When you enter a GSV or SSV instruction, the Logix Designer application displays the object classes, object names, and attribute names for each instruction. This table lists the attributes for the AddOnInstructionDefinition class.

Attribute NameData TypeAttribute Description
MajorRevisionDINTMajor revision number of the Add-On Instruction
MinorRevisionDINTMinor revision number of the Add-On Instruction
NameStringName of the Add-On Instruction
RevisionExtendedTextStringText describing the revision of the Add-On Instruction
VendorStringVendor that created the Add-On Instruction
LastEditDateLINTDate and time stamp of the last edit to an Add-On Instruction
SignatureIDDINT32-bit instruction signature value
SafetySignatureIDDINT32-bit safety instruction signature value